Mitsubishi Ppc Server

Includes support for Wonderware FastDDE AND Suitelink! - More

MC Works64 supports several protocols using the MX OPC Server, allowing connection with various Mitsubishi Electric factory automation products. By using the OPC server manufactured by partner, Takebishi Corporation, other company's controllers can be connected. MX OPC UA server. Support OPC UA functionality. Monitor and operate equipment with. OS compatibility. All operating systems are 64-bit versions. With a client computer for Web browser monitoring, the software can be used with either 32-bit or 64-bit version of Windows ® OS (Professional, Enterprise, and Ultimate editions). Operation with an Embedded system is not guaranteed. OPC Server for Mitsubishi PPC-CPU 852(MS)-128. OPC Server for Mitsubishi Q Series PLCs. OPC Server for Mitsubishi Q00CPU. OPC Server for Mitsubishi Q00JCPU.


Mitsubishi opc server list This Suite contains 5 drivers providing a wide range of connectivity to Mitsubishi PLCs. Click on the links below for details on each driver.

Mitsubishi Opc Server Update

Mitsubishi Ethernet Driver - Device Support

  • PC number support for network bridging
  • Addressable station numbers up to 120 plus 125 and 126
  • Remote access to Net/H networks via bridging through a Q series PLC supported
  • Uses AJ71E71 family of communications cards for A series
  • All A Series and ANA Series PLCs, and Q series PLCs
  • FX3U PLCs
  • L Series PLC
  • QnA Series PLCs
  • iQ-R Series PLCs (via built-in Ethernet port or RJ71EN71 Ethernet module)
  • iQ-F Series PLCs (via built-in Ethernet port)
  • Can also be used for Keyence KV Series PLCs (Click for Details)
  • Memory Types Supported: X, Y, M, B, L, F, TS, TC, TN, CS, CT, CN, D, W, R
  • Memory Type CN Support for 'L' Suffix - Specifies Long Data Type
  • Memory Type ZR Support (Q Series Only)
  • Support for Extended Data Registers (Q Series Only)
  • Support for Extended Link Registers (Q Series Only)
  • All data types are supported
  • String support for W-Link registers included
  • Supports synchronizing PLC clock to the PC clock functions
  • Supports Random Writes on some models for multiple writes per request increasing write performance
  • Configurable read/write block sizes to enable increased read/write performance

Mitsubishi CNC Ethernet Driver - Device Support

  • PC number support for network bridging
  • Uses AJ71E71 family of communications cards for A series
  • C64 CNC Controllers
  • Memory Types Supported: X, Y, M, B, L, F, TS, TC, TN, CS, CT, CN, D, W, R
  • Memory Types Supported (Q Specific): DX, DY, SB, Sm, V, SS, SC, SN, SD, SW, Z
  • All data types are supported

Mitsubishi A/Q Serial Driver Device Support

Mitsubishi Ppc Server
  • Mitsubishi A and ANA Series PLCs using the AJ71C24 / AJ71UC24 family of communications cards
  • Mitsubishi Q series PLCs using QJ71C24N cards
  • Q Series network number setting supported
  • A Series PC number setting supported
  • Supports RS-232 or RS-422 multidrop
  • Multiple data formats such as Long Word are supported
  • Protocols: Format 1 with Checksum Enabled for A Series, Format 5 with Checksum Enabled for Q Series
  • User configurable word order in 32 bit data types
  • Remote access to Net/H networks via bridging through a Q series PLC supported
  • This driver also supports telephone dialup modems
  • This driver also supports Encapsulated Ethernet Mode which provides provide data exchange between OPC Clients and serial devices connected to an Ethernet serial port server device such as Lantronix, Digi, Comtrol, and others. Learn more about Ethernet Encapsulation.

Mitsubishi FX Programming Port Serial Driver Device Support

  • Direct Interface to RS-422 PLC Programming Port via any 232/422 convertor
  • Multiple simultaneous PC Com ports supported
  • All FX, All FX0, All FX0n, FX3U, All FX2n series
  • Multiple data formats such as Long Word are supported
  • This driver supports telephone dialup modems
  • This driver supports Encapsulated Ethernet Mode which provides provide data exchange between OPC Clients and serial devices connected to an Ethernet serial port server device such as Lantronix, Digi, Comtrol, and others. Learn more about Ethernet Encapsulation.

Mitsubishi FX-Net RS-485 Multidrop Driver Device Support

  • Connect up to 16 PLCs to a single com port
  • Multiple simultaneous Com ports supported
  • Interfaces to PLCs via the FX-485PC-IF module on the PLC
  • All FX, All FX2C, All FX0N,FX3U, and All FX2N Model PLCs
  • Multiple data formats such as Long Word are supported
  • This driver also supports telephone dialup modems
  • This driver also supports Encapsulated Ethernet Mode which provides provide data exchange between OPC Clients and serial devices connected to an Ethernet serial port server device such as Lantronix, Digi, Comtrol, and others. Learn more about Ethernet Encapsulation.

Operating System Support:


Click for full details of current TOP Server Operating System Support and Specifications

Mitsubishi Opc Server List


This communications driver is a member of the TOP Server family of products and shares a number of powerful features in common with all of the products in the TOP Server family. The TOP Server family represents the latest in client-server communications technology for connecting HMI, Historian, Database, and other applications to plant floor equipment.

Broad OPC Technology Support
The TOP Server implements a wide range of OPC specifications, including OPC DA, OPC UA, OPC AE, OPC .NET and OPC HDA. Click here for full details of the current OPC Specifications and Versions Supported

This level of OPC support gives you the choice of the widest range of OPC client applications. The TOP Server is continuously tested with the most popular OPC client applications on the market to insure ease of use, integration, and reliability, including popular names as Wonderware, Siemens WinCC, Intellution, Iconics, Cimplicity, RSView and more.

Full Support for Wonderware SuiteLink and FastDDE
The TOP Server's support of Wonderware SuiteLink simplifies the task of connecting the server with Wonderware applications such as InTouch, Historian and System Platform. By using the Wonderware connectivity toolkit, our TOP Server can simultaneously provide OPC and FastDDE/SuiteLink connectivity to address your communications needs (make sure to select this interface from the Native Client Interfaces when installing TOP Server). With built-in support of these Client/Server technologies, the TOP Server allows you to quickly access device data without the need to use an intermediary software bridge (i.e. OI Gateway, formerly known as FSGateway) as is done when using a strictly OPC only communications server. For Wonderware users, the familiar look and feel of FastDDE/SuiteLink tag database setup is maintained. Backwards compatibility for legacy DDE is also supported.

Intellution NIO/PDB native interface supported - no OPC Power Tool needed!
Direct connection to the iFix Process Database allows you to skip the OPC Power Tool. Enabling the iFix PDB interface in TOP Server under File | Project Properties allows TOP Server to appear as a native Intellution driver named 'IDS' (make sure to select this interface from the Native Client Interfaces when installing TOP Server). Never before has connecting TOP Server to Intellution iFix been easier.

Legacy Support for DDE
While OPC has become the most common choice for communications drivers in the automation market, we realize that not everyone can replace their client software with the latest OPC technology. For this reason, TOP Server is one of the few OPC servers on the market to also simultaneously support Wonderware's FastDDE and Suitelink interfaces, Rockwell's AdvanceDDE and Microsoft's standard DDE interfaces for connecting the TOP Server to your client application. With the TOP Server, you can connect to your legacy DDE clients today and move smoothly to the world of OPC when you are ready and not have to worry about replacing or re-configuring the communications driver connecting you to your production machinery.

Other Key Features in the TOP Server

Runtime Configuration Changes A very unique feature to this product is the ability to change your configuration while the server is running and has clients connected. The connected client application has access to an expansive group of system tags that allow the client to request the TOP Server to change a number of different settings at runtime.

Online Full Time The TOP Server allows you to make changes to your tag database configuration at any time. In older versions, you could be online, but not add tags, or be offline to add tags but not read data. With the TOP Server you make changes when you need to, on the fly.

User Management With powerful features such as online changes, you want to make sure you manage who is allowed to make certain changes. The User Manager in the TOP Server lets you define what different people can change and update in the servers' configuration.

Security Policies Plug-in Aside from standard user management, the included Security Policies plug-in for TOP Server provides even further granular control of access by users with respect to what changes can and cannot be made by certain users, including all the way down to the individual channel, device and even tag level. You must be using an OPC UA client application in order to benefit from this plug in as the OPC UA standard supports passing OPC UA authentication.

Mitsubishi Opc Server Download

Tag Management You want to organize your tag database around your process. With the TOP Server we've taken full advantage of OPC grouping capabilities to let you segregate and organize your tags the way you want them. Drag and Drop configuration lets you quickly move, add, copy large numbers of tags quickly and easily. CSV (Ascii comma-delimited) format import and export lets you bring in your tags from an Excel worksheet or export them, edit them in bulk and bring them back in.

Tag Scaling Display your data in units that are meaningful to you. The TOP Server supports Linear and Square Root tag scaling. You define the display format and the engineering units display string to meet your needs.

Diagnostics The TOP Server family of communications products provides real-time OPC diagnostics for all tag read/write operations between TOP Server and your OPC clients (DA and UA) to keep tabs on what is going on in the server. For those tough to debug communications problems, you can turn on our communication diagnostics and capture protocol packets off to disk to find out what is really happening between the computer and the hardware device.

Redundancy The TOP Server includes a Media-Level Redundancy plug-in at no additional cost (simply select it from the list of available option while installing TOP Server). Easily configure redundant paths for redundant devices and redundant communication connections to the same device as part of your device configurations in TOP Server. Automatic failover handling is flexible, with multiple options for how to trigger a failover.

Other Powerful Features in the TOP Server include:

  • OPC Tag Browsing
  • Modem support built-in for serial drivers
  • Ethernet encapsulation support built-in for most serial drivers
  • Auto-demotion (i.e. slow polling) support
  • Extensive help files and examples of how to use the TOP Server with popular OPC clients
  • Visual Basic OPC client sample code
  • 32-bit high performance multi-threaded drivers
  • Run as a Windows service for unattended operation
  • Works with any OPC client or DDE, AdvancedDDE client application
  • Works with Wonderware's FastDDE and SuiteLink interfaces